Defects

Report variable in report functions is translated incorrectly.



ID:    D24427
Published:    08 May 2017
Updated:    13 September 2017
 

Defect Id

DEF301904

Originally Reported Against

ChangeMan ZMF 8.1.3

Resolved In

ChangeMan ZMF 8.1.4
ChangeMan ZMF 8.1.4

Status

Implemented

Description

When running reports (option A.G.R;2) the "Report Variable" is translated incorrectly.  Pressing <enter> changes lower case to uppercase and uppercase to blank, causing the report to fail with the following error message: 

"ERROR: Input parameter error:  SUBSYSTEM LETTER INVALID FROM DATE TOO SHORT FROM DATE INVALID" 

For example:
CMNREPT6                     Report Selection List          Row 11 to 20 of 35 
 Command ===>                                                  Scroll ===> CSR  
                                                                                
 Application mnemonic . . . . DEMO                                             
 Package Number . . . . . . . 437                                               
 Report Variable  . . . . . . ASMPJW1                                        +  
...

After pressing <enter> this is changed to 

 CMNREPT6                     Report Selection List          Row 11 to 20 of 35 
 Command ===>                                                  Scroll ===> CSR  
                                                                                
 Application mnemonic . . . . DEMO                                             
 Package Number . . . . . . . 437                                               
 Report Variable  . . . . . .       1                                        +  
...

Resolution

Please access KB article S142137 for the ZMF 8.1.3 compatible hotfix for this issue.