Find Answers

Filter Search Results
All Operating Systems:
All Products:

All Solution Types:
Source:
 
Ask a Question
Example: "Database could not be verified"  
Tips | Start Over | Solutions | Alerts | Patches | Defects  
Pages [Next]
  Results
CMS-XML ABEND806-04 in DB2PL Step of CMN32 job
ABEND806-04 in DB2 PL Step of CMN32 job
CMS-XML Demotion Bind Error In DB2PL, when a DBB only bind is changed to DBB + PKG bind.
Demotion Bind Error In DB2 PL , when a DBB only bind is changed to DBB + PKG bind.
CMS-XML OWNER and QUALIFIER are not templated correctly when multiple LOGICAL DB2s are processed by CMNDB2PL
The OWNER and QUALIFIER bind parms are not being templated correctly for the 2nd set of bind cards. The customer omits OWNER and QUALIFIER from their input bind cards, and expects DB2 PL to insert the values based on the presence of INSERTQUAL and AUTHORITY=OWNER,INSERT ( DB2 PL control cards). The insert values for OWNER and QAULIFIER in the second set of bind cards is incorrectly set to the values from the first set of bind cards.
CMS-XML CMNDB2PL - format error
If the last line of data in PLAN BIND statements ends in column 71 AND the DB2 PL input cards contain 'AUTHORITY=OWNER,INSERT' DB2PL inserts the '-' (to indicate continuation) in col 73. the BIND will fail with an 806 attempting to execute program 'OWNER(SPTSTAR5)' (the inserted line).
CMS-XML CMNDB2PL hangs when the TRACE parm is uncommented
When running CMNDB2PL with the TRACE parm uncommented, the program hangs indefinitely, until cancelled. If you disable the TRACE parm (comment out), DB2 PL runs successfully. Recreate steps.
CMS-XML S0C4 in CMNDB2PL at offset 12F4 when "source" template is entirely filled.
Using the "search and replace" templating technique in DB2 PL , if you completely fill the "source" column" you will encounter a S0C4 in CMNDB2 PL at offset 12F4. For example, the SRCQUALTEMPLATE has a max length of 8. If you supply a template that is 8 bytes long, you will encounter the S0C4. For example...
CMS-XML SB78-04 abend in 5.6.3 CMNDB2PL
IEA705I ERROR DURING GETMAIN SYS CODE = B78-04 Z3EH08T DB2 PL 00
CMS-XML Invalid IEC190I running CMNDB2PL on z/OS 2.1 system
16.44.55 JOB00963 IEC190I P008967P, DB2 PL ,TDB0BCTL INVALID DCBE: DCBE ID IS NOT 'DCBE'
CMS-XML Various problems in 6.1.1.02 CMNDB2PL
b) CMNDB2PL writes nothing to the temporary bind control file when PLAN(-----) is specified resulting in required bind commands being missed. c) failed allocation of transient DB2 PL file resulting in a step RC=12 and the following errors: 12.57.50 JOB02430
CMS-XML S878 abends running CMNDB2PL for large numbers of components
Sample error messages: 02.08.58 J0151311 IEA705I ERROR DURING GETMAIN SYS CODE = 878-10 40E1D6C2 DB2 PL 80 02.08.58 J0151311 IEA705I 00F93300 008E6858 008E6858 00E61240 00000360
Pages [Next]

Welcome kb sso

My Recent Searches

Search Feedback

Are we answering your questions?

Additional Assistance

  • Submit a Case Online
  • FAQs