  Results
PDF ChangeMan 7.1 Customization Guide
BINDLIST= Optional Force the method used to analyze the structure of a load module YES Scan the binder listing at the BAT90LST DD statement NO Scan every load module in the library at the BAT 90 IN DD statement If the BINDLIST execution parameter is omitted , CMNBAT 90 attempts to open DDname BAT90LST DD and scan the binder listing first. If that fails, the program scans members in the library at the BAT90IN DD statement.
PDF ChangeMan ZMF 8.1 Customization Guide
Valid values: XLMOD Suppress load module analysis. Use this option when the build output members at DDname BAT90IN are either non-load modules, or load modules that cannot contain statically linked subprograms, like BMS MAP load or IMS MFS load. Abbreviation: X YES Scan the binder listing at the BAT90LST DD statement for statically linked subprograms.
PDF ChangeMan 7.1.2 Customization Guide
Valid values: XLMOD Suppress load module analysis. Use this option when the build output members at DDname BAT90IN are either non-load modules, or load modules that cannot contain statically linked subprograms, like BMS MAP load or IMS MFS load. Abbreviation: X YES Scan the binder listing at the BAT90LST DD statement for statically linked subprograms.
PDF ChangeMan ZMF 7.1 Messages
Explanation: No BAT90LST DD statement was found. The BAT90LST DD statement allocates the binder SYSPRINT listing for input to program CMNBAT90. If no binder listing is allocated, CMNBAT90 sets RC=4 and uses the load module scan method to analyze subroutine-to-load relationships.
PDF ChangeMan ZMF 7.1.2 Messages
Explanation: No BAT90LST DD statement was found. The BAT90LST DD statement allocates the binder SYSPRINT listing for input to program CMNBAT90. If no binder listing is allocated, CMNBAT90 sets RC=4 and uses the load module scan method to analyze subroutine-to-load relationships.
CMS-XML Misleading CMNBAT90 CMN4574A message identifies incorrect file in error
A customer developed a new build procedure and received the following error and a RC=4 from a CMNBAT 90 step: CMN4574A - Unable to open BAT90LST file, subroutine analysis will continue by scanning BAT 90 LIB only. CMN5400I - Time of day at end of job: 05:52:09 - Condition Code on exit: 04 ... However, a valid BAT90LST file was being passed to the build procedure. ... 12.14.41 JOB22822 IEC130I BAT 90 WRK DD STATEMENT MISSING
PDF ChangeMan ZMF Customization Guide
* *DDNAME:BT 90 LOS. BAT90LST * ******************************************************************************** ... CMNBAT 90 //SYSIN DD control statements .
CMS-XML HPSTRANS with missing DD statement results in RC=20
HPSTRANS with missing DD statement results in RC=20
CMS-XML CICS MAP compile failing with 'SYSLIN DD STATEMENT MISSING'
CICS MAP compile failing with 'SYSLIN DD STATEMENT MISSING '
CMS-XML IEC130I SYSUTx DD STATEMENT MISSING after select option 5 - clear then specify UNIX files in shortcut
IEC130I SYSUTx DD STATEMENT MISSING after select option 5 - clear then specify UNIX files in shortcut