|
Results |
|
File shows as no longer under DS control after executing the area rename script
Executing the area rename script (Solution 5001609) does not allow a change to the folder structure.
|
|
|
Dim: LSBL command takes too long to process when there are many baselines
Customer is using a script and the command line command LSBL to retrieve the baselines in a product. They are searching for a specific baseline. The LSBL command, and subsequent processing are taking too long for their purposes.
|
|
|
Dim 12: )REP statement contains too many variables and exceeds the limit in a JCL line of 80 characters long
The following in a JCL deployment script fails as the line exceeds the limit of 80 characters per line : )REP DMFILENAME DMPRODUCT DMID DMVARIANT DMTYPE DMREVISION DMWSID DMWSPRODUCT For example, the last variable DMWSPRODUCT exceeds the 80 caracters limit.
|
|
|
Investment tree takes a long time to load causing Mariner to run slowly overall (workaround)
On some systems, you may notice overall poor performance in Mariner that is caused by the investment tree loading slowly. This document will discuss this issue and give a workaround script .
|
|
|
P4DTI operation refresh.py may take an extremely long time on some systems.
This is because currently, the refresh.py Python script re-synchronizes ALL TeamTrack (Business Mashups) items with ALL Perforce Changelists since the inception of the integration. If this integration has been in place, it may be trying to syncrhonize hundreds of thousands of records.
|
|
|
I canÂft find the Text Long Fields 11-20 in the tables selection in Crystal Report
You will need to contact Customer Support to receive a script that will build custom field view for the Custom Field Tables in Project Office. The script is called script_BuildCustomFieldViews.sql.
|
|
|
How To: #1028 Create a local input script (User receives an Error 1; run fine from command-line but not from CB script call)
SOLUTION: The command-line is too long , so use a local input script . To create/use an local input script: -------------------------------------------------------------
|
|
|
Dim10: Why does upgrading to Dimensions 10.x mean my tablespaces (esp pcms_idx) increase substantially? (upgrade takes long time)
Unpack the attached file into /tmp, edit analyze_indices.sh and change SYSTEM's password and base database name to match your system, then run the shell script. The script will produce a list of all indices in the base database along with total blocks allocated/block used counts (3rd and 4th columns of the output respectively). If your system's sort utility supports numeric sorting on given column, then the list shall be ordered by total allocated block count.
|
|
|
5.7.2.11 - Freeze takes unusually long time after upgrade to 5.7.2.
Make procedures reading script is improved (..\sql\ scripts \build_load_full.sql). Variable condition is replaced with constant one.
|
|
|
How To: #1535 MSVC++ 4.0 Build Script
Building a MSVC++ 4.0 Project # into a TOOLS.INI file..., as long as you specify %set theScript=$[Filelist,*.mak] %set numScripts=0
|
|
|