CMS-XML ‘Compare to Baseline/Promotion...’ does not allow for SRD files
ChangeMan ZMF Client Pack 7.1.3.02ChangeMan ZMF Client Pack ZMF 4ECL 7.1.3.02
CMS-XML ZMF4ECL - Checkout does set levels correctly for SRD baselines.
ChangeMan ZMF Client Pack 7.1.2
CMS-XML Invalid ERR0302 if copybook previously baselined in SRD with ignored changes
In CMN ZMF 5.5.2 Serena provided a way of allowing customers to specify the significant columns for a component being updated in a stacked reverse delta ( SRD ) dataset. For example, by adding the TEXT($PLI) parameter to CMNUPDAT only columns 1-72 will be compared and changes in the line number columns (73-80) will be ignored when the component is updated in the baseline and delta libraries.
CMS-XML CMNUPDAT/SRD problems managing lrecl=255 components
A customer stores their C source code in datasets with a logical record length of 255 bytes and uses stacked reverse deltas (SRDs) to house this data in their baseline libraries. Since their upgrade from ZMF 5.5 to 5.6 they have encountered two distinct problems at package baseline time (i.e. during CMNUPDAT processing):
CMS-XML Baseline browse SRD minus level IEC988I messages and exclusive enque of baseline delta library not released.
Browse baseline of a minus level baseline delta data set issues several IEC988I messages. It also puts an exclusive enque on baseline delta data set which is does not release until the user exits the ZMF ISPF client.
CMS-XML Incorrect time value when viewing SRD stack
Fixed in ZMF 5.5.3.
CMS-XML Time display error in SRD stack persists
ChangeMan ZMF 5.6.1
CMS-XML CMNUPDAT Not Transferring ISPF Statistics to SRD
ChangeMan ZMF 7.1.1.02 Hotfix
CMS-XML CMN5114A SRD minus baseline must be RECFM=FB LRECL=80 when defining delta libraries with FB/LRECL greater than 80
ChangeMan ZMF 7.1.3.03
CMS-XML Stacked Reverse Delta loses old version of component after SCRATCH and reuse of same name.
ChangeMan ZMF 8.1.4ChangeMan ZMF 8.1.4
Pages [Next]

Welcome kb sso

My Recent Searches

Search Feedback

Are we answering your questions?

Product Demos

Dimensions CM: Comparing files (demonstration)
This Dimensions CM demonstration shows you how to compare two item revisions in the repository, and compare an item revision in the repository with a file in a work area

Additional Assistance

  • Submit a Case Online
  • FAQs