CMS-XML DB2 -- error code 0000000C -- reason code 00F30040
Explanation: The allocation of the plan to the connection failed . Either
CMS-XML 'PDS830E OBTAIN error; DSCB not on volume' results when EDIT command used twice in a row against a sequential dataset
‘PDS830E OBTAIN error; DSCB not on volume’ ... DB ... Error ‘PDS830E OBTAIN error; DSCB not on volume’ will result ... PDSDSNP -------------------- Change Command Failed ---------------------------- ... Change allocation failure ; please correct data set parameters and press ENTER:
CMS-XML Linear Vsam with CISIZE > 4096 results in error PDS999E ABEND S08B U0000 AT A0605A
R4 : 814D0 DB 0 R5 : 814D03A8 R6 : 014C8B90 *R7 : 049FDFAA ... ABEND08B RC1D IS RECEIVED IF THE VSAM LINEAR DS USED BY DIV HAS ... Failure to do so will result into an ABEND08B RC1D issued by
CMS-XML IF THEN(SUBLIST) processing of PDS results in S878-10
DB DB2 - Menu of DB2 services APPLID - ISR ... IEA030I OPEN FAILED FOR DUMP DATA SET FOR ST
CMS-XML DSNT408I SQLCODE = -104 when inserting a new row into a DB2 table.
1.From the main FDM panel select DB . ... 9. PF3 and you get the following message: PDS#304Q SQL INSERT or UPDATE for some changes failed , SAVE not allowed
CMS-XML accessing IAM dataset results in S0C9-0009 U0000 AT +00000352 IN PROGRAM PDSIDC :(@DIAIDC )
6: 00000000/1B3 DB 94E 7: 00000000/00116000 8: 00000000/9B3 DB 580 9: 00000000/001157F0 ... PUTGET Service failed ; RC=24
CMS-XML GIM54502E ** ALLOCATION FAILED FOR PDSELOD
The following SMP/E error is received when attempting to install the PDS#OPT4 options module using the SMP/E SMP#OPT4 JCL: GIM54502E ** ALLOCATION FAILED FOR PDSELOD BECAUSE THERE IS NO DD STATEMENT IN THE JCL AND NO DDDEF ENTRY IN TARGET ZONE STAT.
CMS-XML GIM54601S Dynamic Allocation Failed For SYSLIB Because HASPSRC Is Part Of The SYSLIB Concatenation
Product: StarTool-FDM version 7.5.1 Product: During an APPLY check, the following error messages were received . APPLY GEXT BYPASS(HOLDSYSTEM)
CMS-XML using FIND, get error "Read multiple failed" followed by 'Permanent I/O error'
When using the FIND command to search for a string, the results were listed as expected, but when PF3 to the Startool main menu, and do a FIND again on the same string and data, the following error was received : >------> Find '163226' IGNORE NUM
CMS-XML PDS730E Dynamic mlib/plib definition failed with S0C1 at +000358 in PDSIDSPY
Using #DYNLIB in the PDS#OPT4 options module to allocate the FDM libraries, the user receives PDS730e followed by a S0C1. PDS730E DYNAMIC PLIB/MLIB DEFINITION FAILED PDS999E ABEND S0C1 U0000 AT +000358 IN PROGRAM PDSIDSPY