Find Answers

Filter Search Results
All Operating Systems:
All Products:
All Solution Types:
Source:
 
Ask a Question
Example: "Database could not be verified"  
Tips | Start Over | Solutions | Alerts | Patches | Defects  
Pages [Next]
  Results
CMS-XML STRB15E MO= parameter is invalid for MAXOUT parameter
Execution of the following JCL results in STRB15E for the MAXOUT parameter even if it is spelled out: DD01 MULTICOPY ME=15,MO=10, --- STRB15E MO= parameter is invalid
CMS-XML FDM720: COMPR does not copy members using PDSFAST interface
'&&TEMP' has been created on volume AXTW12 PDF0101I START PDSFAST EXECUTION PDF0103C COPY O=SYS01741,LIST=NO,I=SYS01740
CMS-XML IEW4000I FETCH FOR MODULE IDCLC01 FROM DDNAME -LNKLST - insufficient storage
Workaround: Reduce the number of datasets invoked in a single execution .
CMS-XML 'Search For' option 3.14 displays input dsn instead of output dsn with model
COMMAND ===> Foreground execution ==> NO (YES for Foreground, NO for batch) Input data set ==> 'STRSUP.FDM762M.CNTL'
CMS-XML z/OS 2.4 Compatibility with ChangeMan ZMF, ChangeMan SSM, Comparex, StarTool FDM and StarTool IOO
Customers must be running one of these product releases to remain on a supported configuration. No other releases of these products will be certified for execution on z/OS 2.4.
CMS-XML multiple simultaneous 'delete' jobs against same data set leaves deleted members
If FDM 7.7.0 is used, all members are deleted. sample execution SDSF DA S001 S001 PAG 0 CPU/L 40/ 18 LINE 1-7 (7)
CMS-XML z/OS 2.5 Compatibility with ChangeMan ZMF, ChangeMan ZMF Client Pack, ChangeMan SSM, Comparex, StarTool FDM and StarTool IOO
for execution on z/OS 2.5. If a Micro Focus product upgrade is required to maintain compatibility, we recommend that customers choose the latest available version and maintenance release that supports their chosen version of the operating system.
CMS-XML SER10TY 4.3.1 Patch
The software associated with SER10TY 4.3.1 is bundled in the file named SER10TY 4.3.1.exe. Upon execution , 3 files will be extracted.
CMS-XML S80A using FIXPDS RELEXTENT
COMPR PDF0101I START PDSFAST EXECUTION PDF0103C DEFAULT COPY OUTDD=SYSUT2,INDD=SYSUT1 * GENERATED *
CMS-XML HIST/ATTRIB command performance issues - increased CPU and EXCP times - S0F4 abends
Execution time – notice increase in CPU and EXCP time from the 7.6 to 7.7 versions. These numbers increase as library size increases.
Pages [Next]

Welcome kb sso

My Recent Searches

Search Feedback

Are we answering your questions?

Additional Assistance

  • Submit a Case Online
  • FAQs