CMS-XML Getting error "PDS961E VSAM GET error at RBA=00038466
Getting error "PDS961E VSAM GET error at RBA=00038466
CMS-XML COPYREC of empty vsam to flat file gets inserted record if PDS961E VSAM GET error occurs
COPYREC of empty vsam to flat file gets inserted record if PDS961E VSAM GET error occurs
CMS-XML VERIFY against IAM vsam dataset gets error ISPP100 Panel 'PDSM1VE' error
VERIFY against IAM vsam dataset gets the following error: ------------------ StarTool 7.8.0 Dialog Error on 2016/02/04 ------------ OPTION ===>
CMS-XML PDS#101A PDS961E VSAM POINT error
rs=9C An invalid control interval was detected during keyed processing, an addressed GET UPD request failed because the control interval flag was
CMS-XML PBrowse/PVIEW of VSAM data set results in PDS961E VSAM POINT error at RBA=00000000; Feedback=D708009C
- An invalid control interval was detected during keyed processing - an addressed GET UPD request failed because the control interval flag was on
CMS-XML ESDS VSAM: PDS961E VSAM OPEN / ERROR; RC=0008;Open failed ; Feedback=000000A0
fdm 7.8.0.033 gets open error for empty ESDS VSAM dataset Allocate an ESDS vsam dataset -----------------------------
CMS-XML Running IAM 9.1/01P and getting VSAM DATA SET HAS NOT BEEN INITIALIZED, USE FIX RESET.
After upgrading IAM release from 9.0/04P to 9.1/01P the following error occurred when calling the browse or edit function with an existing IAM file. The message issued is:
CMS-XML error processing a null or empty VSAM data set
will get : IEC161I 072-053,userid,procname,ddname,dsname PDS831E Unable to open data set and StarTool will prompt for a different data set.
CMS-XML Linear Vsam with CISIZE > 4096 results in error PDS999E ABEND S08B U0000 AT A0605A
Failure to do so will result into an ABEND08B RC1D issued by div module ITVXM which is checking the CISIZE to be equal to 4096 Bytes during DIV data set open processing.
CMS-XML FDM: copybook getting error on comment line
FDM: copybook getting error on comment line
Pages [Next]

Welcome kb sso

My Recent Searches

Search Feedback

Are we answering your questions?

Product Demos

Dimensions CM: Updating a work area from a stream (demonstration)
This Dimensions CM demonstration shows you how to update a work area from a stream, restrict the update to specific folders in the stream, and exclude files from the update.
Dimensions CM: Working with Items, Part 2 (demonstration)
This Dimensions CM demonstration shows you how to copy item revisions to a work area using the Get and Update commands, deliver a modified file from a work area to a stream using the Deliver command, and action an item revision

Additional Assistance

  • Submit a Case Online
  • FAQs