CMS-XML STR720: PDS999E S0C4 error when accessing StarTool from the linklist
PDS999E ABEND S0C4 U0000 AT +071954 IN PROGRAM PDS IKJ56641I PDS ENDED DUE TO ERROR + IKJ56641I SYSTEM ABEND CODE 0C4 REASON CODE 00000011
CMS-XML STR710: Accessing VSAM dataset result in message "PDS945E This data set is in use by CICS...
Product: StarTool Version 7.1.0 Detail: Accessing a VSAM dataset results in error message " SHR PDS945 E This data set is in use by CICSxxxx" for those dataset that are SHR, OPEN and ENABLED by CICS.
CMS-XML IAM dataset access results in PDS971E IAM_ANAL has completed; RC=32; IAM "IAMFDMEX" MODULE NOT FOUND
Attempting to access an IAM dataset with FDM results in the following error : PDS971E IAM_ANAL has completed; RC=32; IAM "IAMFDMEX" MODULE NOT FOUND
CMS-XML pedit/pview displays incorrect record counts and PDS892E Read multiple failed
2) Select "Type of data set access ==>LOAD or NOLOAD " 3)
CMS-XML FDM730/741: PDS961E VSAM POINT error at RBA=00000000 using pbrowse with PATH
Detail: Attempting to access the alternate index via the path results in the following error and an incomplete feedback code. - I am able to access the alternate index and esds directly. - I am able to access the alternate index using IDCAMS, so I know the path is okay.
CMS-XML COPYREC of empty vsam to flat file gets inserted record if PDS961E VSAM GET error occurs
PDS200I DISP UNIT RECFM LRECL BLKSIZE ALLOCTRK FREETRK SECONDARY DSORG PDS200I SHR 3390 VSAM 1000 1000 1X 15 0 1 CYL VS-KSDS STRB02I EXCP input is in use, access as data
CMS-XML ICH408I ACCESS INTENT(UPDATE) followed by PDS831E when using Option 1-browse - browse methods 1,2, or 3 against VSAM data set
3) use browse method= 1 (1= Browse..... browse method=1,2,3 produce the same errors 4) hit enter - ICH408I error results
CMS-XML ESDS VSAM: PDS961E VSAM OPEN / ERROR; RC=0008;Open failed ; Feedback=000000A0
3. You are not authorized to access the data set.
CMS-XML COPYREC results in PDS961E VSAM PUT error
PDS200I DISP UNIT RECFM LRECL BLKSIZE ALLOCTRK FREETRK SECONDARY DSORG PDS200I SHR 3390 VSAM 50 800 1X 15 0 1 CYL VS-KSDS STRB02I EXCP input is in use, access as data
CMS-XML ATTRIB command results in erroneous PDS705E
Install FDM 7.7.0.2 patch P2507. Specify P2507 under 'Ask a Question' to access the patch.