  Results
CMS-XML Control block definition CICS0410EIUS & CICS0410TMELD errors
Reading about the EIUS, it seems it may not exist for every program. However, I could find no details about the ' table manager lock block' ??????
CMS-XML S0C4 in module ASMA90 running job to generate the DA system table
TIME=14.27.48 SEQ=00211 CPU=0000 ASID=001A PSW AT TIME OF ERROR 078D1000 95B51FBC ILC 4 INTC 10 ACTIVE LOAD MODULE ADDRESS=15B00488 OFFSET=0005
CMS-XML DA-CICS ESPYAOPE 014E,I/O error(read ),DDname=C"ESPYCFG"
12.25.53 S0015821 +DFHDU0205 ACD2C10A A SYSTEM DUMP FOR DUMPCODE: SR0001 , WAS SUPPRESSED BY THE DUMP TABLE OPTION FOR THIS
CMS-XML ULTI254I... ,RPL Support Table exceeded,...
TIME=18.23.11 SEQ=24771 CPU=0000 ASID=00BD PSW AT TIME OF ERROR 078C1000 8031B10E ILC 2 INTC 0D NO ACTIVE MODULE FOUND
CMS-XML DA510: ESPYAMON 320E,StarSpy WLS ESCT level error,Found C"M003 ",Expected C"V510"
Until you IPL, you can attempt to start StarTool-DA V510 using a different subsystem name. However, you would need to also change the subsystem name in your CICS system table (s) (ATCSs)
CMS-XML ASMA057E Undefined operation code - ESPYE/PROGRAM=xxxxxxxx, after applying DA 5.7.3 cobol 6.1 maintenance
After applying the DA 5.7.3 cobol 6.1 ptf (enhancement ENH281626) with smp/e, the rebuild of 'da svc table ' for the cics components results in the following error : SDSF OUTPUT DISPLAY DDEL0009 J0215745 DSID 110 LINE 1 COLUMNS 01- 80 COMMAND INPUT ===> SCROLL ===> CSR 001D1E 3551+ DS 0H
CMS-XML Copybook with Record Selection using 'NE' not processing using F for full word search
Using PEDIT and copybook with record selection, records are incorrectly being selected that match the ... Enter SAVE to save or enter LOAD to load a previously saved table
CMS-XML WLS abend S0C4 in ESPYAMVS+47E4
10.59.13 STC05334 ESPYAMON 707I,BLDL table cleanup complete ,B7000 R15 RC=X"00000000". ... 265 PSW AT TIME OF ERROR 470C0000 800577E4 ILC 2 INTC 11
CMS-XML ESPYAOPE 016E,"EXEC CICS RECEIVE BUFFER" failure,Resp=X"0051/0000"
ERR =D1 SYSENS=0000 USENS=0000 TASK=DORH TRMNL=DVDG RPLRC=0000 ... VTAM LOSTERM Error Code X'14'. ((2) Module name: ... ERR =19 SYSENS=0000 USENS=0000 TASK=DORH TRMNL=DVDG RPLRC=1009 ... DFHDU0207I 11/25/03 09:55:34 CICSPT02 Transaction and system dumps for dumpcode: AZI6 were suppressed by the DUMP TABLE ... ERR =5C SYSENS=0000 USENS=0000 TASK=DORH TRMNL=DVDG RPLRC=0000
CMS-XML S0C4 in ESPY9DV6 selecting anything within Option 6
_ CVT (System Communication Vector Table ) ... Error Recovery ... Might they have done something incorrectly when installing the levelset?