CMS-XML Batch job hanging due to RTO ENQ on a PDS dataset.
It looks now like the RTO ENQ a PDS dataset in a similar instance. There have been two instances of this ENQ at the customers site. A snippet of the DETECT log is below highlighting the dataset and abend:
CMS-XML SSM830: HPS0104E message when attempting to define a Delta Tracked Object
I have had problem adding a Delta tracked resource to our system. The DETECT Log shows a lot of *put* failures like the following: HPS0104E I/O Area: 4085877E0000014D00000001
CMS-XML SSM832: Getting IEC161I messages running the $BACKSTC job (with RLS enabled)
I have taken the $BACKSTC supplied job in the INSTALL dataset and successfully taken a backup without taking the databases down, however I see the following in the Started task log ... Object Master, and Delta Master without stopping the ChangeMan
CMS-XML HPS0104E R15 = 8 R0 = 3 STAT/FDBK = x'05080004' errors on DELTA Master
The first pass used $INIT to allocate the VSAM files as non-RLS and then we performed some VSAM housekeeping tasks ($INTEG) before logging into the environment. ... Logged into SSM environment and attempted to add objects to one of the groups and encountered numerous errors on Delta master and process failed ... ** Get Failure ** on DEL file cluster CMNP.SSMP.DEV.DELTA.MASTER ... ** Get Failure ** on DEL file cluster CMNP.SSMP.DEV.DELTA.MASTER
CMS-XML SSM821: RC=027 not defined when tracking objects
RC=014-026 Failure to do a GET/PUT operation. Exit to browse LOG .
CMS-XML SSM821 ALIAS not being handled correctly when performing an online define of data sets to change tracking
RC=014-026 Failure to do a GET/PUT operation. Exit to browse LOG .
HTML Serena® ChangeMan® SSM Version 8.2.2 Readme File Last updated on 14 July 2005
6.0 Fixes Update help panel HPSH210 for new RC=578 (Authorization failure ) ... Failure to add. ... Put Failure ** on DEL file cluster SYS3.DR.DPLEX1.DELTA.MASTER ... TSO session loops while trying to delete an object from panel HPSCONG4 ... With SSM RTO running results in BMC CONTROL-M hanging ... Wait seen during DB2 log archive using VTS tape output.
CMS-XML HPS0607E I/0 read failure hotifx
HPS0607E I/0 read failure hotifx
CMS-XML ChangeMan SSM in Recovery-Retry loop
ChangeMan SSM in Recovery-Retry loop
CMS-XML SSM823: HISTORY report looping, and displaying invalid data
SSM823: HISTORY report looping , and displaying invalid data