CMS-XML started task getting s106-0c and s878
... encounters the following errors even when running ... ... 031I LIBRARY ACCESS FAILED FOR MODULE ... ... 031I LIBRARY ACCESS FAILED FOR MODULE ... ... IEA705I ERROR DURING GETMAIN SYS ... ... LIST IS NOT ACCESSIBLE , DCB ADDRESS ... 1D9 E 7 ... LIST IS NOT ACCESSIBLE , DCB ADDRESS ... 1D9 E 7 ... LIST IS NOT ACCESSIBLE , DCB ADDRESS ... 1D9 E 7 ... LIST IS NOT ACCESSIBLE , DCB ADDRESS ... 1D9 E 7 09.39.13 STC11922 SER0999I SerNet server "1" termination complete, RC=16 ... PSW AT TIME OF ERROR : 070C1000 811CC082
CMS-XML compare of PDS members results in CSV026I HPSTRANS NO ACCESSED followed by CSV028I ABEND306-34 JOBNAME=M1GNW00 STEPNAME=
TIME=13.11.09 SEQ=00190 CPU=0000 ASID=0063 PSW AT TIME OF ERROR 070C1000 813A975 E ILC 2 INTC 0D NO ACTIVE MODULE FOUND
CMS-XML SSM831 Message HPS0103E when running the $ADMSET installation job.
This is an indication of the following: 'B6' error code (OPEN) - RLS specified in the HPSPARMS member, but SMSVSAM server is not available. Development provided this helpful link information to assist with questions regarding VSAM return codes.
CMS-XML SSM823: HPS0104E/HPS1308I Messages during a define of data sets to change tracking
Reason Code ( Server Errors ) . . . . . . . . . . . . . . . . . . 144
CMS-XML Incorrect DSORG set when object is defined to multiple groups.
Incorrect DSORG for additional groups, potential for S0C4 abend in HPSSERV during HPSRTO capture. S138 Abend if RLS is not being used, ENQ held preventing access to Master files, including ZMF SSV.
CMS-XML Incorrect DSORG set when object is defined to multiple groups
An incorrect DSORG can occur for additional groups. A potential for S0C4 abend in HPSSERV during HPSRTO capture exists. S138 Abend can occur if RLS is not being used, ENQ held preventing access to Master files, including ZMF SSV.
CMS-XML HPS0100W HPSTRANS * Failure * Dynamic allocation SVC99 error field = x'4704'
From the fingerprint output, the ssm parameters do not specify a volume, thus the catalog is being used to access the datasets. Fingerprint job - done by dataset name.... thus, dataset accessed via catalog and not volume From fingerprint job
CMS-XML SSM832 16D Abend accessing the SSM ISPF facility - avoidance solution.
TIME=19.59.59 SEQ=05795 CPU=0000 ASID=0193 PSW AT TIME OF ERROR 070C1000 81681CEA ILC 2 INTC 0D NO ACTIVE MODULE FOUND
CMS-XML Data reporting error within the RTO when a BACKUP has completed.
09.29.20 J0199020 IRR010I USERID ??????? IS ASSIGNED TO THIS JOB. 09.29.20 J0199020 ICH70001I ??????? LAST ACCESS AT 09:25:42 ON THURSDAY, NOVEMBER 13, 2008 09.29.20 J0199020 $HASP373 ???????P STARTED - INIT 2 - CLASS 1 - SYS TN01
CMS-XML SSM $BACKSTC hangs in multiple SSM STC environment following errors in RTCT operation integrity processing
564 IEC161I CATP.PSYSEP.USRCAT02 HPS3017I HPSBACK 07:38:07 SSM Backup job waiting for access to master files. HPS3017I HPSBACK 08:10:08 SSM Backup job waiting for access to master files.