CMS-XML Update of a PDSE results in error IEC143I 213-3C
EDIT ------> Replace ** ' USER =A810350' ' USER =A810 ... 000002 PDS831E Unable to open data set ... IEC143I 213-3C,IGG0191A, USERID ,ISPFS001,SYS00010,04AF,SRSMAF,USERID.PDSE.PDS3 ... Offset of error : 00007334 ... PSW AT TIME OF ERROR 075C1000 80DDD812 ILC 2 INTC 0D
CMS-XML FIXPDS RESET reults in PDS831E Unable to open data set or S0C1
Using PGM=IKJEFT01 in batch to perform a FIXPDS RESET of a standard PDS load library, the following message occurs: PDS831E Unable to open data set ... PDS298I There are 2 users allocated to this data set ... PDS831E Unable to open data set ... In online mode, a s0c1 occurs or the user is sent back to the FDM menu - either PDSMENU or PDS@PRIM ... 0 Parameters - Specify StarTool parameters USERID - DUSERID ... PSW AT TIME OF ERROR 078D0000 000FF6A0 ILC 2 INTC 01
CMS-XML ICH408I ACCESS INTENT(UPDATE) followed by PDS831E when using Option 1-browse - browse methods 1,2, or 3 against VSAM data set
ICH408I ACCESS INTENT(UPDATE) followed by PDS831E UNABLE to OPEN DATA SET incorrectly issued when using ... browse method=1,2,3 produce the same errors 4) hit enter - ICH408I error results ICH408I USER ( userid ) GROUP( USER ) NAME( user name ) ... IEC161I 040(056,006,IGG0CLFT)-002, userid ,ISPFS001ISPFS001,SYS00061,,, ... SHR e PDS831E Unable to open data set e
CMS-XML IF THEN(SUBLIST) processing of PDS results in S878-10
0 Parameters - Specify StarTool parameters USERID - DDELXXX ... PSW AT TIME OF ERROR 070C1000 815A18D6 ILC 2 INTC 0D ... IEA705I ERROR DURING GETMAIN SYS CODE = 80A-10 DDELXXX ISPFS001 ISPFS001 00 ... IEA705I ERROR DURING GETMAIN SYS CODE = 878-10 DDELXXX ISPFS001 ISPFS001 00 ... IEA030I OPEN FAILED FOR DUMP DATA SET FOR ST
CMS-XML Starbat MULTICOPY IF input tape concatenation gets STRB50E or IEC141I 013-34
... STRB50E error message or IEC ... 13-34 error message. ... Resulting output showing error message: opened for QSAM output ... Resulting output show error message ... 0920,, userid 8,S ... ... 0917,, userid 8,S ... ... 0931,, userid 8,S ... ... 0199G, userid 8,S ... ... AT TIME OF ERROR 075C1000 ... ... IEF450I userid 8 S08 ... ... ,PVT, userid 8,S ... IEF234E K 080E,MP0917,PVT, userid 8,S08A IEF234E K 0809,MP0931,PVT, userid 8,S08A
CMS-XML PDS961E VSAM OPEN error at RBA=0000; Open for update failed Feedback=000801F0
From the FDM messages manual indicating that the data set is already opened for output by some user , task or job. rs=F0, "Open for update failed" (the data set is open elsewhere or not reusable and an OPEN for UPDATE failed.
CMS-XML PBROWSE against multivolume dataset gets error UNABLE TO OPEN DATASET
PBROWSE against multivolume dataset gets error UNABLE TO OPEN DATASET
CMS-XML LICDSN jobs gets assembly error 'ASMA416C Unable to open DECK file'
Licensing job in CNTL(LICDSN) receives the following assembly errors : ** ASMA416C Unable to open DECK file HIGH LEVEL ASSEMBLER - INTERRUPT AND DIAGNOSTIC DUMP HLASM R5.0
CMS-XML ISPT034 TABLE IS NOT OPEN error when invoking FDM using dynamic allocation of FDM libraries
ISPT034 TABLE IS NOT OPEN error when invoking FDM using dynamic allocation of FDM libraries
CMS-XML ESDS VSAM: PDS961E VSAM OPEN / ERROR; RC=0008;Open failed ; Feedback=000000A0
fdm 7.8.0.033 gets open error for empty ESDS VSAM dataset Allocate an ESDS vsam dataset -----------------------------